Synthes tfna inventory. Product Codes : 03.010.127, 03.010.048, 04.003.240S... View Mor...

Edit your synforms tfna inventory form form online. Type text, com

Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESThe brutal truth about the housing market's new Ice Age: If you don't already own a home, you're going to be screwed for years to come. Jump to If you don't already own a home, you...TFN-ADVANCED™ Implant only. ON. Static / Rotational Locking. ON. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. visualized by pixelmolkerei.ch. Interactive 3D Web application by pixelmolkerei.02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.View and Download Synthes The Titanium Femoral Nail System technique manual online. Solid and Cannulated Nails. The Titanium Femoral Nail System medical equipment pdf …J5294-F 10/12 These implants and instruments are available nonsterile or sterile-packed. Add S to catalog number to order sterile product. Inventory Control Form Titanium Cannulated Humeral Nail-EX System Patient Information: SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To.INVENTORY CONTROL FORM Case Information (eg, Case ID): Synthes USA Products, LLC To order: (800) 523-0322 Synthes (Canada) Ltd. To order: (800) 668-1119 RIA 2 Reamer Irrigator Aspirator Date: Hospital: Surgeon: Procedure: Y N D Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 ... Procedure: Titanium Cannulated Tibial Nails-EX, with Proximal bend, sterile Patient Information: J7976-F 5/13 Inventory Control Form Titanium Cannulated Tibial Nail-EX, with Proximal bend 8.0 mm diameter LENGTH LENGTH 04.034.231S 255 mm 04.034.234S 270 ...Fillable it inventory management software liberate. Collection about most popularly forms in a given sphere. Fill, sign and send anytime, anywhere, from any device with pdfFiller. Support. Log in. Solutions. Solutions. Discover how pdfFiller helps couples process documents faster, collect data or approvals, plus more.Variable Angle LCP™ Elbow System. Product Codes: 02.107.002, 02.107.002S, 02.107.102... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle LCP™ Elbow System utilizes the variable angle locking technology platform that is based on a common approach to implant design and instrumentation, reducing complexity and ensuring a familiar ...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 Inventory Control Form Titanium Modular Mini Fragment LCP System 2.0 mm, 2.4 mm and 2.7 mm Instrument and Implant Modules 2.0 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH ...For the treatment of Femoral shaft fracture, Subtochanteric, and combined femoral neck & Shaft fractures. #mycompany # DePuySynthes # JnJSYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J3901-H 5/13 Inventory Control Form Titanium Cannulated Trochanteric Fixation Nail System Titanium Cannulated Trochanteric Fixation Nails, 10 mm distal diameter, sterile FEMORAL RIGHT LEFT ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J8398B 7/09 Inventory Control Form 3.7 mm Cannulated Locking and Conical Screws 3.7 mm Cannulated Locking Screws 3.7 mm Cannulated Conical Screws 02.240.210 10 mm 02.240.212 12 mm 02.240.214 14 ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J8398B 7/09 Inventory Control Form 3.7 mm Cannulated Locking and Conical Screws 3.7 mm Cannulated Locking Screws 3.7 mm Cannulated Conical Screws 02.240.210 10 mm 02.240.212 12 mm 02.240.214 14 ...Inventory Control Form. TFN-ADVANCED™. Proximal Femoral Nailing System. Implants. (continued)Instruments. Available non sterile and sterile packed. Add “S” to catalog number to order sterile product. Guide Wires Part # Description 357.399 3.2 mm Guide Wire, 400 mm 09.037.010 3.2 mm Guide Wire, 475 mm 03.045.018 3.2 mm Guide Wire with ...By MDBR Staff Writer 25 Mar 2015. DePuy Synthes Companies of Johnson & Johnson has introduced new TFN-Advanced Proximal Femoral Nailing System (TFNA), developed to improve surgical treatment of hip fractures. The new nail, blade and screw system integrates a bump cut design that makes the nail stronger and is made by using a titanium alloy.A catalog excerpt of the TFNA nail system, a proximal femoral nail with rotational and static locking options. The catalog compares the static locking performance of the TFNA with other similar nails and provides …DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.TFNA - Proximal Femoral Nailing System The Universal Nail System Titanium/Stainless Steel Elastic Nail System UFN Unreamed Femoral Nail CFN Cannulated Femoral Nail UHN/PHN Humeral Nailing System UTN/CTN Solid/Cannulated Tibial Nail Please read these instructions for use, the Synthes brochure "Important Informa-tion" carefully before use.Inventory Control Form LCP Dynamic Helical Hip System (DHHS) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5047-E 2/11 LCP DHHS Compression Screw 211.890 4.5 mm Cortex Screws, self-tapping LENGTH 214.828 28 mm 214.830 30 mm 214.832 32 mm ...Follow the step-by-step instructions listed below to electronically sign your synthes tna inventory: Choose the paper you want to sign and click the Upload button. Hit the My Signature button. Decide on what kind of electronic signature to make. You can find 3 options; a typed, drawn or uploaded eSignature.The Synthes TFNA is with evolution to the Synthes PFNA. It has many traits in common with most proximal femoral nails for fragility fractures, the proximal end holds a larger diameter higher standard nails to increase fit in osteoporotic boning, distortive to end starting of short spike is tapered additionally there is right one separate ...4 DePuy Synthes Femoral Neck System (FNS) Surgical Technique Indications, Contraindications, and Warnings Indications The Femoral Neck System (FNS) is indicated for femoral neck fractures, including basilar, transcervical, and subcapital fractures, in adults and adolescents (12-21) in which the growth plates have fused or will not be crossed.by the AO and DePuy Synthes and belong still to sur - geons basic armatorium used for fracture treatment, revision surgery and correction osteotomies. Due to their fixed-angle shape, successful application needs planning, concise orientation in all planes (AP and lateral views, rotation) and preparation of the channel for the blade. IntroductionSep 1, 2021 · The TFN-ADVANCED (TFNA) Proximal Femoral Nailing System (DePuy Synthes) is a cephalomedullary nail intended for the treatment of proximal femoral fractures. Although nail breakages are infrequent, a recent implant retrieval study of 16 broken TFNA nails in Western Australia reported that the TFNA presented with a unique fracture pattern, with a ...Background: The TFNA (Trochanteric Fixation Nail Advanced) Proximal Femoral Nailing System (DePuy Synthes) is frequently used for intramedullary fixation of proximal femoral fractures.Page 63 Miss-A-Nail Locking (continued) Insert the second screw using the same technique. Insert the nail Proceed with standard nail insertion technique (pages 21–25). Insert the second screw Drill for shaft screw Insert the 3.2 mm calibrated Insert the 5.0 mm guide wire through the sleeve shaft screw and into the femoral head until it is ...Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°TRAUMACEM™ V+ Augmentation System. Product Codes : 03.702.121S, 03.702.150S, 07.702.040S. View More. PRODUCT CODES. DESCRIPTION. The TRAUMACEM™ V+ System is a polymethylmethacrylate (PMMA) cement indicated for augmentation of the TFN-ADVANCED™ Proximal Femoral Nailing System. Its applicator allows surgeons to inject cement into the ...01. Edit your synthes dhs one step inventory control form online. Type text, add images, blackout confidential details, add comments, highlights and more. 02. Sign it in a few clicks. Draw your signature, type it, upload its image, or use your mobile device as a signature pad. 03. Share your form with others.Our Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients. Get In Touch With a Sales Consultant.October 30, 2017 By Fink Densford. Johnson & Johnson (NYSE: JNJ) subsidiary DePuy Synthes said today it launched the TFNA augmentation system designed to treat patients with hip fractures who have ...The Synthes TFNA is an evolution of the Synthes PFNA. It has many features in common with most proximal femoral nails for fragility fractures, the proximal end has a larger diameter than standard nails to increase fit in osteoporotic bone, distally the end of the short nail is tapered and there is just a single locking bolt to reduce the stress ...The Synthes TFNA system offers both solid and fenestrated helical blade and lag screw options. The fenestrated head elements allow for cement augmentation. There is some evidence that augmented fixation may have a lower rate of failure in osteoporotic individuals, however evidence demonstrating superiority of cement …The Titanium Cannulated Adolescent Lateral Entry Femoral Nail is an expert nailing system with radiolucent instrumentation. It includes: End Caps. Easy-to-use instrumentation facilitates the surgical procedure. Standard Locking Screws. 5 mm Recon Screws. Get in Touch with a Sales Consultant.The tips below will help you complete Synthes Tfn Inventory easily and quickly: Open the template in our feature-rich online editing tool by clicking on Get form. Fill out the requested fields that are yellow-colored. Press the green arrow with the inscription Next to move on from one field to another. Use the e-signature solution to add an ...TFNAdvanced is a system for intramedullary fixation of proximal femoral fractures. It consists of nails, implants, instruments and augmentation devices. See indications, contraindications, surgical technique and clinical cases.Now, working with ampere Synthes Inventory Controlling Download requires a maximum of 5 minutes. Our state web-based voids the obvious guidelines eliminate human-prone errors. Treatment guidelines leads to individual leitung also potential. Adhere to our comfortable steps to receive your Synthes General Command Form well prepared quickly:TFNA - Système d'enclouage fémoral proximal Système de clou universel Système de clou élastique en titane/acier inoxydable Clou fémoral sans alésage (UFN)/canulé (CFN) Système d'enclouage huméral UHN/PHN Clou tibial plein/canulé UTN/CTN Avant toute utilisation, lire attentivement ce mode d'emploi et la noticeInventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, …3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add "S" to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 10 holes, 177 mm, rightWhen it comes to purchasing a used truck, finding a reliable dealer with a vast inventory is crucial. One name that stands out in the trucking industry is Lone Mountain Truck Inven...TFN-ADVANCED® Proximal Femoral Nailing System (TFNA) • Surgical Technique 5 Indications, Contraindications, and Precautions Indications The TFN-ADVANCED …4 DePuy Synthes TFN – Titanium Trochanteric Fixation Nail System Surgical Technique 11 0 100 1,0001 0,000 100,000 25° 20° 15° 10° 5° 0 TFN TFN 80° 70° 60° 50° 40° 30° 20° 10° 0 11 0 100 1,000 10,000 100,000 Biomechanical FeaturesNA0525 TFNA SOFT CASE FOR STERILE NAILS BLADES AND SCREWS 1 Move To; Top of this tray Bottom of this tray; A different tray... Remove 04.037.042S 10MM/130 DEG TI CANN TFNA 170MM ... The custom kit capabilities sole purpose is for convenience of inventory and device usage identification.TFNA, kurz, Länge 200 mm Rechts Durchmesser (mm) Femurhalswinkel 04.037.913S 9 125° 04.037.943S 9 130° 04.037.973S 9 135° 04.037.013S 10 125° 04.037.043S 10 130° 04.037.073S 10 135° 04.037.113S 11 125° 04.037.143S 11 130° 04.037.173S 11 135° 04.037.213S 12 125° 04.037.243S 12 130° 04.037.273S 12 135° TFNA, kurz, Länge 235 …Introduction The recently developed femoral neck system (FNS) for treatment of femoral neck fractures (FNF), comprises theoretical biomechanical advantages compared to other implants. The aim of this study was to validate the safety and to report outcomes of patients treated with the FNS. Method A retrospective multicentric analysis of patients treated by FNS with a minimum of three months of ...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...To fill out the SynForms DHS Inventory, follow these steps: 1. Obtain the SynForms DHS Inventory document from the appropriate source or download it from the designated platform. 2. Read the instructions provided with the form to understand the purpose and specific requirements of the inventory. 3.LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).When it comes to purchasing a used truck, finding a reliable dealer with a vast inventory is crucial. One name that stands out in the trucking industry is Lone Mountain Truck Inven...Alexander Hofmann, Martin Hessmann800-410-8177. [email protected]. 2021 Reimbursement Guide DePuy Synthes 3. The DePuy Synthes MAXFRAME®Multi-Axial Correction System is indicated for the following treatments in adults and in both children (3-12) and adolescents (12-21) in which the growth plates have fused or will not be crossed with hardware: Fracture ...Inventory Control Form 2.0 mm Quick Insertion Screw (QIS) and 2.0, 2.5, 3.0, 3.5, 4.0 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 ...Synthes TFNA FENESTRATED SCREW 110 mm Condition: Used 04.038.210 Synthes TFNA FENESTRATED SCREW 110 mm. $270.00 Add to Cart ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 240-050-988 Stryker SDC Ultra™ Image Management System ...The Synthes TFNA is with evolution to the Synthes PFNA. It has many traits in common with most proximal femoral nails for fragility fractures, the proximal end holds a larger diameter higher standard nails to increase fit in osteoporotic boning, distortive to end starting of short spike is tapered additionally there is right one separate ...TFNA, kort, lengte 170 mm Rechts Diam. (mm) Hoek femurhals 04.037.912S 9 125° 04.037.942S 9 130° 04.037.972S 9 135° 04.037.012S 10 125° 04.037.042S 10 130° 04.037.072S 10 135° 04.037.112S 11 125° 04.037.142S 11 130° 04.037.172S 11 135° 04.037.212S 12 125° 04.037.242S 12 130° 04.037.272S 12 135° TFNA, kort, lengte 200 mmThe Titanium Sternal Fixation System provides internal fixation of the sternum for primary or secondary closure and repair. 1,2. Get in Touch with a Sales Consultant.Distal: 9-12 mm, in 1-mm-Abstufungen (kurze Nägel) 9, 10, 12, 14 mm (lange Nägel) Kurze Nägel: 170 mm extrakurz 200 mm kurz 240 mm (ein Nagel passend für links und rechts) Lange Nägel: 300 mm-420 mm (linke und rechte Nägel, in 20-mm-Abstufungen) CCD-Winkel 125° und 130° Zusätzlich 135° für Nägel, Länge 240 mm.This PDF document is a form for recording the implants used in tibial nailing procedures with the TN-ADVANCEDTM system. It lists the part numbers, lengths and quantities of the implants available in the inventory.Abstract. Hip fractures are a major public health problem, resulting in substantial patient pain, mortality, and financial cost. The TFN-ADVANCED (TFNA) …Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ...of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactThe Expert Tibial Nail permits an intra medullary approach for the fixation of proximal, shaft and distal fractures of the tibia. The system consists of a series of cannulated nails, can-nulated end caps, dual core locking screws and standard locking screws. All of the implants are made of titanium alloy (TAN*).Backgrounds This study aimed to analyze the clinical outcomes of femoral neck fractures (FNF) in patients treated with a femoral neck system (FNS, DePuy Synthes), which is a recently introduced device. Methods This retrospective cohort study of 43 patients who underwent osteosynthesis using FNS for FNF between July 2019 and June 2021 with a minimum follow-up of 6 months. The researchers ...Now that summer is over, it's a good time to log into your airline and hotel accounts. Check to see how many points or miles you have, when they expire and check for any leftover c...Quick guide on how to complete tfna synthes inventory. Forget about scanning and printing out forms. Use our detailed instructions to fill out and eSign your documents online. airSlate SignNow's web-based program is specifically created to simplify the arrangement of workflow and optimize the entire process of proficient document management.Synthes TFNA FENESTRATED SCREW 115 mm Condition: Used 04.038.215 Synthes TFNA FENESTRATED SCREW 115 mm. $270.00 Add to Cart ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 240-050-988 Stryker SDC Ultra™ Image Management System ...Inventory Control Form QIS AND 2.0 MM CANNULATED SCREW SYSTEM PLUS (CSS+) Head Height: 1.65 mm Washer and Head Construct Height: 1.44 mm Thread Length Short Thread: approx. 25% Total Length or 4 mm Long Thread: approx. 40% Total Length Thread Length Head Height Construct Height Length Washers Part Number 04.353.900.05 Washer For 2.0 Cann Screw .... INVENTORY CONTROL FORM Tibial Nail Advanced System ImSynthes products supplied in a non-sterile condition must be cleaned a TFNA – Sistema de clavos femorales proximales Dispositivo de mira distal (DAD) para clavos universales simplificados (S.U.N.) ... Los productos de Synthes que no se suministran estériles deben limpiarse y esteri - lizarse en autoclave con anterioridad a su aplicación quirúrgica. Antes de proceder TFNA, kort, lengte 170 mm Rechts Diam. (mm) Hoek femur DePuy Synthes: $2.2 billion in orthopedic sales in first quarter 2022 sales; DePuy Synthes parent company Johnson & Johnson has $23.4 billion in sales total in the same quarter. Stryker: $4.3 billion in first quarter 2022 sales. Zimmer Biomet: $1.7 billion in first quarter 2022 sales. 2. Number of employees.The Synthes TFNA system offers both solid and fenestrated helical blade and lag screw options. The fenestrated head elements allow for cement augmentation. There is some evidence that augmented fixation may have a lower rate of failure in osteoporotic individuals, however evidence demonstrating superiority of cement … The Large External Fixation System uses a modular construction...

Continue Reading