Synthes small cchs inventory. Cannulated Compression Headless Screw (CCHS) System. CCHS offers...

Catalog Number: 105.185. Set includes implants, instru

Learn how to use the Cannulated Compression Headless Screws (CCHS) System for bone fixation in various anatomical regions. Find the product information, instrument list, set …Catalog Number: 105.135. Set is comprised of an assortment of 4.0 mm cannulated stainless steel screws (short thread and long thread), instrumentation and storage. Multiple assortments available. CLICK HERE for list of set components that include both non-threaded (292.626) and threaded guide wires (292.62).Europe, Middle East and Africa ( EN) Germany ( DE) Israel ( HE) Spain ( ES)Background/Purpose Posterior pelvis ring injuries represent typical high-energy trauma injuries in young adults. Joint stabilization with two cannulated sacroiliac (SI) screws at the level of sacral vertebrae S1 and S2 is a well-established procedure. However, high failure- and implant removal (IR) rates have been reported. Especially, the washer recovery can pose the most difficult part of ...awl or a periosteal elevator through a small skin incision with a minimum of soft-tissue dissection. (2, 3) 2. Perform percutaneous pinning If the fragment is correctly reduced, perform percutaneous pinning. 3. Implant removal In case the physician decides to remove the implants, implants can be removed by using general surgical umr t n. ss ent i- 95° Condylar Plates (Adolescent and Small Stature Adult) - Femoral neck and pertrochanteric fractures - Plates - 130° Angled Blade Plates (Adolescent and Small Stature Adult) No contraindication specific to these devices. Cannulated Screws 3.0/3.5/4.0/4.5/6.5/ 7.0/7.3 CSS 3.0 Fixation of fractures of the forearm, hand and foot, e.g.:Universal Small Fragment System System Catalog DePuy Synthes 2 Instruments Core System Trays Anatomic Implant Trays Case & Lid Options Set Information Table of Contents Case & Lid Options 40 Graphics Cases 41 ... 399.19 Small Hohmann Retractor 8 mm Short Narrow Tip 160 mm 399.49 Hohmann Retractor 15 mm 160 mmThe 4.0mm Cannulated Screw Set utilizes a self-drilling, self-tapping screw tip which facilitates screw insertion by eliminating the need for pre-drilling and tapping in most cases. The 4.0mm Cannulated Screws set utilizes and 2.5mm hexagonal screwdriver commonly found in many small bone fixation sets.In any business, effective inventory management is crucial for success. It involves the process of overseeing and controlling the flow of goods from the moment they are acquired to...Quick steps to complete and e-sign Synthes small fragment inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes.Synthes Modular Foot Inventory. Check out how easy it is to complete and eSign documents online using fillable templates and a powerful editor. ... Orthopedic Equipment Synthes USA Feb 1, 2012 — RADIOGRAPHIC RULER FOR SMALL FRAGMENT PLATES 360MM. EA. $390.00. $359.34. 7.86%. N. 100 03.111.001. T-HANDLE FOR MIDFOOT FUSION BOLT. (PDF) Dynamic ...Synthes Small External Fixator Set (186.430) Top Tray Drill Bits Catalog # Description 310.19 2.0 mm Drill Bit, Quick-Coupling, 100 mm 310.20 2.0 mm Jacobs Chuck Drill Bit, 85 mm 395.91 Drill Sleeve Handle 395.92 4.0 mm Drill Sleeve 395.93 2.0 mm/2.5 mm Drill Sleeve 395.94 2.5 mm Trocar K-Wires Catalog # DescriptionAdhere to this straightforward instruction to redact Synthes 3 7 cannulated inventory in PDF format online for free: Sign up and sign in. Create a free account, set a secure password, and go through email verification to start managing your forms. Add a document. Click on New Document and select the form importing option: add Synthes 3 7 ...The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010Synthes 2.8 mm Cobalt-Base Alloy Threaded Guide Wire 300 mm Synthes 2.8 mm Cleaning Stylet For 7.3 mm Cannulated Screws Join Our Email List Visit MPR Orthopedics. A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.Synthes Small Fragment Set Inventory Sheet Vijai Singh,Ajay Kumar A Social History of Knowledge II Peter Burke,2013-04-17 Peter Burke follows up his magisterial Social History of Knowledge, picking up where the first volume left off around 1750 at the publication of the French Encyclopédie and following the story through to Wikipedia.Make the steps listed below to improve your Synthes cchs small inventory online: Open required sample from the catalog. Fill out the blanks with Text and drop Check and Cross tools to the tickboxes. Use the right-side toolbar to alter the form with new fillable areas. Choose the areas depending on the type of information you wish to be ...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010A number of high-profile firms and startups have set up logistics networks in India in the last decade as they attempt to digitize neighborhood stores. Bangalore-headquartered star...Complete Synthes Cannulated Compression Headless Screw Inventory Control Form online with US Legal Forms. Easily fill out PDF blank, edit, and sign them. Save or instantly send your ready documents.Clinical characteristics. Congenital central hypoventilation syndrome (CCHS) represents the extreme manifestation of autonomic nervous system dysregulation (ANSD) with the hallmark of disordered respiratory control. The age of initial recognition of CCHS ranges from neonatal onset (i.e., in the first 30 days of life) to (less commonly) later ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ...02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.8 DePuy Synthes VECTRA Surgical Technique B4. Break cortex Required instruments 324.111 Awl 2.5 mm with trocar tip 03.613.001 Drill and Screw Guide, for VECTRA and VECTRA-T Introduce the Drill and Screw Guide in the small posthole of the plate. Insert the awl in the Drill and Screw Guide and push down while simultaneously twisting the awl4 DePuy Synthes Small Fragment Locking Compression Plate (LCP ®) System Surgical Technique. AO Principles. In 1958, the AO formulated four basic principles, which . 1 4 2 3. 4_Priciples_03.pdf 1 05.07.12 12:08. 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique. AO PRINCIPLES. In 1958, the AO formulated four basic principles, whichSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants P J3266-K 3/11 Inventory Control Form DHS/DCS & DHS/DCS One-Step Insertion plvllllpklgulpu. † NT NT 4 16 mm 212.106 20 mm 212.108 4 4.x NT NT 44 4 4 16 mm 4 18 mm 4 20 mm 4 22 mm 44 4 4mm 4 28 mm 4 30 …Variable Angle LCP™ Proximal Tibia Plate (3.5 mm) 02.211.201, 02.211.201S, 02.211.202... Part of the Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques, this plate provides a fixed-angle construct while allowing surgeons the freedom to choose the screw trajectory before ...• Small Fragment Locking Instrument Set (103.502) • Small Fragment Locking Screw Set (103.517) • Small Fragment LCP Plate Set (103.516) ... DePuy Synthes StarDrive vs Hex Static Torsion Test. 2011. #SET_20110610. Screw Reference Chart Thread Diameter 2.7 mm 3.5 mm 4.0 mm Screw Type Cortex Locking CancellousDePuy Synthes CCHS Screw Cutting Performance Memo. 29th Jan 2020. Windchill # 0000288513. 3. ... Axial load of small group n=15, medium group n>10, large group n=6 were measured. Test groups were DePuy Synthes CCHS 6.5 and 7.5 mm, HCS 6.5 mm, and Stryker Fixos 2 7.0 mm screws. †Memo Guide Wire Material (Windchill # 0000287828). CoCr Guide ...Find company research, competitor information, contact details & financial data for Synthes Usa Products, LLC of West Chester, PA. Get the latest business insights from Dun & Bradstreet.Synthes Small Cchs Inventory Control Form Printable Form, Templates. Web the depuy synthes matrixmandible plating system consists of a variety of plates that come in multiple shapes and sizes to. Web the depuy synthes matrixmandible plate and screw system is intended for oral, maxillofacial surgery. Web the synthes matrixmandible subcondylar ...DePuy Synthes CCHS & CSS+ vs. Stryker® Fixos®/Fixos 2, Stryker ® Asnis Micro/Asnis III & Acumed Acutrak® 2 DePuy Synthes 2.5 CCHS & CSS+ Stryker 2.5 Fixos Acumed 2.5 Acutrak2 Micro DePuy Synthes 3.0 CCHS & CSS+ Stryker 3.0 Asnis Micro III Mean Axial Load (N) 90 80 70 60 50 40 30 20 10 0 DePuy Synthes 4.0 CCHS & CSS+ Stryker 4.0 Fixos ...Inventory Control Form RFN-ADVANCED™ Retrograde Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): RFN-ADVANCED™ System Ø 9 mm Diameter Nail, Sterile Standard Bend Periprosthetic Bend Length (mm) 04.233.916S 04.233.917S 160 mm 04.233.920S 04.233.921S 200 mm 04.233.924S 04.233.925S 240 mmLearn how to use the Cannulated Compression Headless Screws (CCHS) System for bone fixation in various anatomical regions. Find the product information, instrument list, set list, and MRI information for CCHS inventory.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10199-A 10/10 2.4 mm Titanium Cortex Screws, self-tapping Inventory Control Form 2.4 mm Titanium VA-LCP Intercarpal Fusion Plate System LENGTH (mm) LENGTH (mm) 401.756 6 401.757 7 401.758 8 401 ...INVENTORY CONTROL FORM Case Information (eg, Case ID): Synthes USA Products, LLC To order: (800) 523-0322 Synthes (Canada) Ltd. To order: (800) 668-1119 RIA 2 Reamer Irrigator Aspirator Date: Hospital: Surgeon: Procedure: Y N D Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada.The Universal Small Fragment System consists of two components: 1) A core set of instruments, screws, and standard implants; and 2) modular anatomic implant trays for the supported small fragment anatomy. In addition, the core set can support all 2.7 mm/3.5 mm DePuy Synthes non-locking, LCP ®, and VA LCP ® plating technologies.Introduction. Congenital central hypoventilation syndrome (CCHS) is a rare genetic disorder of the autonomic nervous system (ANS) and respiratory control due to a mutation in the paired-like homeobox 2B (PHOX2B) gene found on chromosome 4.1 CCHS patients usually present in the newborn period with apnea, hypoxemia, and hypoventilation that are most severe during sleep, particularly during ...Complete DePuy Synthes Inventory Control Form Small Fragment LCP System 2011-2024 online with US Legal Forms. Easily fill out PDF blank, edit, and sign them. Save or instantly send your ready documents. We use cookies to improve security, personalize the user experience, enhance our marketing activities (including cooperating with our marketing ...Buy discounted Depuy Synthes products online, search WestCMR's extensive catalog of spine and trauma products, distal radius plate, total knee joint reconstruction, and more Depuy Synthes devices & instruments.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5632-H 11/12 Inventory Control Form Titanium Cannulated Tibial Nail-EX Titanium Cannulated Tibial Nail-EX, sterile 8.0 mm diameter LENGTH LENGTH 04.004.231S 255 mm 04.004.234S 270 mm 04.004 ...Completed Synthes Kits . 1.2021 . Synthes Small Fragment Instrument & Implant Set w/Self-Tapping Screws | 105.408 Synthes Locking Small Fragment LCP Instrument & Implant Set w/Self-Tapping Screws | 105.434 Synthes Mini Fragment Instrument & Implant Set w/Self-Tapping Screws | 105.488 Synthes Large Fragment LCP Instrument Set | 115.401INVENTORY CONTROL FORM 2.7 mm LCP™ Ulna Osteotomy System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Please contact your sales consultant for items approved for sale in Canada.This document shows the inventory of implants and instruments for the Titanium Humeral Nail-EX System, a device for fracture fixation of the humerus. It includes the product codes, lengths, and quantities of each item, as well as the contact information of SYNTHES (USA) and SYNTHES (Canada) Ltd.Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate - Low Bend. 4.5 mm LCP Proximal Tibia Plate.Introduction. Congenital central hypoventilation syndrome (CCHS) is a rare genetic disorder of the autonomic nervous system (ANS) and respiratory control due to a mutation in the paired-like homeobox 2B (PHOX2B) gene found on chromosome 4.1 CCHS patients usually present in the newborn period with apnea, hypoxemia, and hypoventilation that are most severe during sleep, particularly during ...8 Synthes LCP Anterolateral Distal Tibia Plate 3.5 Technique Guide 1 Preparation Required set (one of the following) 182.400 LCP Compact Small Fragment Instrument Set with Locking Screws Stardrive 3.5 mm and Implants (Pure Titanium) in Vario Case 182.405 LCP Compact Small Fragment Instrument Set with Locking Screws Stardrive 3.5 mmCannulated Compression Headless Screw (CCHS) System. CCHS offers surgeons uncompromised precision through: Cutting edge for improved cutting efficiency. Cobalt Chrome Guide Wire for less deflection. Most comprehensive portfolio on the market to address a wide range of surgical needs. 1. The CCHS implants are titanium, differential thread pitch ...Inventory Control Form Large Fragment LCP™ System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. LCPLARGEFRAGICF001v2 07/22 2 *Also available LengthLength 212.215212.201 42 …The system is neatly divided into preconfigured sets—small, medium, and large. These sets house separate screw racks and instrument trays according to size that is designed to provide efficiency in the operating room supply sourcing (Fig 6): Small set: 2.0, 2.5, 3.0, 3.5, and 4.0 mm screws. Medium set: 4.5 and 5.5 mm screwsThe Titanium Elastic Nail (TEN™) System consists of dedicated implants for stable fixation and instruments that facilitate handling. The nail tip facilitates nail insertion and sliding along the medullary canal 1,2 while nail marking allows direct visual control of the alignment of the nail tip in the medullary canal 1,2.Repair Kits Removal Kit Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): FGS-1000 FIBULINK® Syndesmosis Repair Kit, Stainless Steel FGS-1100 FIBULINK® Syndesmosis Repair Kit, Titanium FGS-1300 FIBULINK® Removal Kit FIELDApr 27, 2023 · This site is intended for visitors from North America, South America, Africa, Asia, Europe, Latin America and the Pacific. From this site you can view or print Instructions For Use (IFU) for the Cannulated Compression Headless Screw and Cannulated Screw Systems. Documents should be reviewed before using or implanting a device, or performing ...02.118.408 7 holes, right 02.118.409 7 holes, left. 2.7 mm Variable Angle LCP Distal Tibia T-Plates. 02.118.306 4 holes 02.118.307 6 holes. Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Inventory Control Form. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System.DePuy Synthes Cannulated Compression Headless Screws (CCHS) 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.5, 6.5, 7.5 mm For Fixation of Various Bones and Bone Fragments. Surgical Technique.Clinical characteristics. Congenital central hypoventilation syndrome (CCHS) represents the extreme manifestation of autonomic nervous system dysregulation (ANSD) with the hallmark of disordered respiratory control. The age of initial recognition of CCHS ranges from neonatal onset (i.e., in the first 30 days of life) to (less commonly) …Synthes has not tested compatibility with devices provided by other manufacturers and assumes no liability in such instances. Magnetic Resonance environment Torque, Displacement and Image Artifacts according to ASTM F2213-06, ASTM F 2052-06e1 and ASTM F 2119-07 Non­clinical testing of worst case scenario in a 3 T MRI system did not reveal anyFind company research, competitor information, contact details & financial data for Synthes Usa Products, LLC of West Chester, PA. Get the latest business insights from Dun & Bradstreet.The Variable Angle LCP™ Forefoot-Midfoot System offers a wide range of low-profile plates with variable angle (VA) screw placement and compression system designed within the plates to help minimize additional soft tissue dissection. Available in stainless steel and titanium. Product Specifications.J5294-F 10/12 These implants and instruments are available nonsterile or sterile-packed. Add S to catalog number to order sterile product. Inventory Control Form Titanium Cannulated Humeral Nail-EX System Patient Information: SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To.- 95° Condylar Plates (Adolescent and Small Stature Adult) - Femoral neck and pertrochanteric fractures - Plates - 130° Angled Blade Plates (Adolescent and Small Stature Adult) No contraindication specific to these devices. Cannulated Screws 3.0/3.5/4.0/4.5/6.5/ 7.0/7.3 CSS 3.0 Fixation of fractures of the forearm, hand and foot, e.g.:Inventory Control Form TN-ADVANCED™ Tibial Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TN-ADVANCED™ Tibial Nailing System Ø 8 mm, Sterile Right Part # Length (mm) 04.043.005S 255 mm 04.043.010S 270 mm 04.043.015S 285 mm 04.043.020S 300 mm 04.043.025S 315 mm 04.043.030S 330 mm 04.043.035S 345 mmIn today’s fast-paced business environment, effective inventory management is crucial for success. Properly managing your inventory not only ensures that you have the right product...The Small External Fixation System provides stable fixation for fractures of the small bones including the Distal Radius Fixator for stabilization of distal radius fractures. Designed for fractures of the distal radius, this fixator includes the following components: a 4.0 mm adjustable clamp, 4.0 mm / 3.0 mm self-drilling Schanz screws, and 8. ...of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J4963-E 9/12 Inventory Control Form Modular Hand System Implants and Instruments (Stainless Steel) 200.531 11 mm 200.532 12 mm 200.533 13 mm 200.534 14 mm 200.526 6 mm 200.527 7 mm 200.528 8 mm ...DePuy Synthes is a global leader in medical devices for foot and ankle procedures. Our foot and ankle portfolio is the result of working with healthcare professionals around the globe to develop solutions tailored to the needs of both patients and surgeons. We offer comprehensive solutions for foot and ankle reconstruction, elective and trauma ...Plus, with us, all the info you include in the Synapse Inventory Control Form - Synthes is well-protected against loss or damage by means of top-notch file encryption. The following tips can help you fill out Synapse Inventory Control Form - Synthes easily and quickly: Open the form in the feature-rich online editor by hitting Get form.The Synthes 1.5 mm LCP® Modular Mini Fragment System consists of plates and screws and is intended for fixation of small bones and small bone fragments; osteotomies, arthrodeses, replantations, and reconstructions of small bones and small bone fragments, particularly in osteopenic bone.The 3.5/4.0 mm system may be customized using two of three screw blocks that hold the following screw types: 3.5 mm cannulated cortical; 4.0 mm can-nulated cancellous with a standard head and. 4.0 mm cannulated cancellous (full thread or lag) with a reduced head. Consistent with all Biomet implants, the screws offer the TiMAXTM benefits of ...Study with Quizlet and memorize flashcards containing terms like What sizes come in the small CCHS?, What is included in each separate tray on this set?, For the 2.7 module, what size screws correlate with this and what size guide wires and screw driver shaft should I use? and more.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10175-C 5/11 2.4 mm/2.7 mm VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm VA-LCP Forefoot/Midfoot Plating System 02.211.230 0° right 02.211.231 0° left 02.211.232 5 ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 24 mm 214. .... Figure 1 Small Headless Compression Screws (4Make these fast steps to change the PDF Synthes mini fragment set 2.5 DePuy Synthes CCHS 2.5 Stryk er® ® Fixos® +68% Acumed ® Acutrak 2 Micro +163% More insertion force required Figure 1: Small Headless Compression Screws (40 pcf) 0 10 20 30 40 50 60 Mean Axial Load (N) 6.5 DePuy Synthes CCHS 7.5 DePuy Synthes CCHS 7.0 Stryk er® Fixos 2® +26% (vs 6.5 DPS CCHS) +20% (vs 7.5 DPS … A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] C Study with Quizlet and memorize flashcards containing terms like What sizes come in the small CCHS?, What is included in each separate tray on this set?, For the 2.7 module, …of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact Surgical Technique for HCS 4.5 and 6.5 1. Ins...

Continue Reading