Synthes va prox tibia inventory. The number of homes available for sale is finally improving...

The Arthrex Distal Tibia Plating System was designed for the v

324.003 LISS Insertion Guide for Proximal Tibia, orleft 324.004 LISS Insertion Guide for Proximal Tibia, right1 324.043 Fixation Bolt for LISS Insertion Guide 2 324.044 Stabilization Bolt for LISS Insertion Guide 3 324.022 Drill Sleeve for LISS Insertion Guide 4 321.170 Pin Wrench B 45. mm 5 Note:Synthes 3.5 VA-LCP Proximal Tibia Plates. Shipped with USPS Ground Advantage.The Synthes Ankle Trauma Inventory(SATI) is a comprehensive approach to the management of ankle trauma, designed to provide the necessary resources to address the specific needs of patients with ankle injuries. The SATI is a collaboration between Synthes, a leading provider of medical devices and solutions, and leading ankle trauma experts.The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the …The following tips can help you complete Synthes Va Proximal Tibia Inventory easily and quickly: Open the form in the full-fledged online editing tool by clicking Get form. Fill in the necessary fields that are colored in yellow. Press the arrow with the inscription Next to move from box to box. Go to the e-signature solution to put an ...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5632-H 11/12 Inventory Control Form Titanium Cannulated Tibial Nail-EX Titanium Cannulated Tibial Nail-EX, sterile 8.0 mm diameter LENGTH LENGTH 04.004.231S 255 mm 04.004.234S 270 mm 04.004 ...LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119.INVENTORY CONTROL FORM 3.5 mm LCP Distal Tibia T-Plate Implants (cont’d) Instruments 4.0 mm Cancellous Bone Screws, fully threaded LENGTH LENGTH 206.010 10 mm 206.012 12 mm 206.014 14 mm 206.016 16 mm 206.018 18 mm 206.020 20 mm 206.022 22 mm 206.024 24 mm 206.026 26 mm 206.028 28 mm 206.030 30 mm 206.032 32 mm 206.035 35 mm 206.036 36 mm 206 ...The 4.5 mm LCP Proximal Tibia Plate System has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the 4.5 mm LCP Proximal Tibia Plate System in the MR environment is unknown. Scanning a patient who has thisThe TomoFix Anatomical Medial High Tibial Plate is contoured to provide an anatomical fit. When compared with the TomoFix Standard and small plates, the new design is intended to reduce both implant prominence. and postoperative implant irritation. Fig 1 shows x-rays from one patient. The brands and labels "approved by AO Technical Commission ...Tibia Plate with locking screws. 2.7 mm or 3.5 mm cortex screws may also be used as lag screws through the plate by overdrilling the near fragment. Note: To verify that independent lag screws will not interfere with plate placement, evaluate placement with AP and lateral fluoroscopic image. LCP Distal Tibia Plate • Surgical Technique 5TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges …The Arthrex Distal Tibia Plating System was designed for the versatile treatment of distal tibia fractures.• Includes anterolateral, medial, anterior, and posterior tibia plates; 2.7 mm straight plates; and two styles of posterolateral fibula plates• Particular attention was placed on maintaining a low-profile design by optimizing contour and fit to minimize soft-tissue …The DePuy Synthes VA Locking Attachment Plate 3.5 is offered in Stainless Steel mate - rial in both sterile and non-sterile package configurations. It attaches to DePuy Synthes VA-LCP PPFx Proximal Femur Plate or Proximal Femur Hook Plate 3.5/4.5/5.0, VA-LCP Curved Condylar 4.5/5.0, LCP Curved Condylar 4.5/5.0, Straight and Curved Broad LCPInventory Control Form 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Available nonsterile or sterile-packed. Add "S" to catalog number to order sterile product. 2.7 mm / 3.5 mm Variable Angle LCP Medial Distal Tibia Plates 02.118.002 4 holes, right 02.118.003 4 holes, left 02.118.004 6 holes, right 02.118.005 6 holes, leftThe indications for this 4.5mm plate system are for proximal tibia fractures including lateral splits, depressions, bicondylar splits, medial splits and dissociation from the shaft. It enables a fixed-angle construct in the metaphysis while providing the flexibility of axial compression and locking capability throughout the length of the plate shaft. The head of the plate is …Tibia Plate with locking screws. 2.7 mm or 3.5 mm cortex screws may also be used as lag screws through the plate by overdrilling the near fragment. Note: To verify that independent lag screws will not interfere with plate placement, evaluate placement with AP and lateral fluoroscopic image. LCP Distal Tibia Plate • Surgical Technique 5The DePuy Synthes LCP™ Proximal Femoral Hook Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw technology with conven - ... • LCP Proximal Tibia Plate 4.5/5.0 • LCP Medial Proximal Tibia Plate 4.5/5.0 Locking Compression Plate The Locking Compression Plate (LCP) has combi-holes inThe LCP Low Bend Medial Distal Tibia Plate 3.5 mm is part of the Synthes Small Fragment LCP system that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. Combi-holes provide the flexibility of axial compression and ...The Synthes VA-LCP Condylar Plate 4.5/5.0 system is indi-cated for buttressing multifragmentary distal femur fractures including: supra-condylar, intra-articular and extra-articular condylar fractures, periprosthetic fractures, fractures in normal or osteopenic bone, nonunions and malunions. VA-LCP Condylar Plate 4.5/5.0 Technique Guide Synthes 5The VA Locking Calcaneal Plating System is designed to treat complex fractures with multiple fixation points targeting key areas of hard cortical bone in the calcaneus. It consists of plates and screws with variable angle locking technology to offer a variety of options for fixation. Product Specifications. How to Use This Product.Like the weather, the housing market usually cools in the fall. Will the coronavirus make this year different? By clicking "TRY IT", I agree to receive newsletters and promotions f...– Proximal Lateral Tibia: See technique guide Less Invasive Stabilization System (LISS) for Proximal Lateral Tibia (036.000.203) Using the guiding blocks for LCP DF and PLT The guiding blocks allow easy and correct mounting of the threaded LCP drill sleeves in the head of the plate. Instruments 312.940/941 Guiding Block for LCP PLT, right/leftAbout This Product. The Synthes Olecranon Plates System consists of VA-LCP Proximal Olecranon Plates, VA-LCP Proximal Olecranon Plates and VA-LCP Proximal Ulna Plates and different type of Screws used with the plate. Such as. Locking Screws Ø 3.5 mm. Cortex Screws Ø 3.5 mm. Low Profile Cortex Screws Ø 3.5 mm. VA Locking Screw Ø 2.7 mm.The aim of this study was to evaluate the clinical and/or radiologic outcome using different polyaxial locking plates for the treatment of proximal tibia fractures, the Non-Contact-Briding plate (NCB-PT®) by Zimmer or the Variable Angle Locking Compression Plate (VA-LCP®) by Synthes. This study enrolled 28 patients with proximal tibia …The new 3.5/4.5 Variable Angle LCP Periprosthetic Proximal Femur Plating System was developed for treatment of Vancouver types A and B fractures. It is offered in stainless steel. The modular system consists of anatomically pre-shaped plates with variable angle locking screw technology. The versatility of the system allows the surgeon to connect the plate components in various configurations ...The Synthes Proximal Femur Plates family of implantable devices consist of LCP™ Proximal Femoral Plate 4.5/5.0 and Synthes LCP™ Proximal Femoral Hook Plate 4.5/5.0 and are available in various sizes in both sterile ... TomoFix ® Medial High Tibia Plate; VA LCP™ Periprosthetic Proximal Femur Plating System; Knee. Knee Arthroplasty. AOX ...The Synthes 3.5 mm VA-LCP Proximal Tibia Plates are intended to treat fractures of the proximal tibia in adults and adolescents in which the growth plates have fused including: simple, comminuted, lateral wedge, depression, medial wedge, bicondylar combination of lateral wedge and depression, periprosthetic, and fractures with associated shaft ...AA Medical Store improves healthcare around the world by supplying refurbished state-of the-art surgical devices at the best price, with the best warranty, and unmatched service and support.4.5 mm VA LCP Curved Condylar Plates Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Holes Length 02.124.406 6, Right 159 mm 02.124.407 6, Left 159 mm 02.124.408 8, Right 195 mm 02.124.409 8, Left 195 mm 10, Right 230 mm 230 mm 266 mm 266 mm 301 mm 301 mm 336 mm 336 mm 370 mm 370 mmUse the Torque Limiter 1.5 Nm (511.115) and the Screwdriver Shaft (Hex 314.030, Stardrive 314.116) for the motor-driven insertion of the locking screw. Stop the motor before locking, fix the torque limiter and the screw-driver shaft to the Handle with Quick Coupling (311.431) and tighten the screw. After one click, the optimal torque is reached.The aim of this study was to evaluate the clinical and/or radiologic outcome using different polyaxial locking plates for the treatment of proximal tibia fractures, the Non-Contact-Briding plate (NCB-PT®) by Zimmer or the Variable Angle Locking Compression Plate (VA-LCP®) by Synthes. This study enrolled 28 patients with proximal tibia fractures (AO/ OTA 41 B-C) and indication for locking ...DESCRIPTION. Our 2.7/3.5 mm LCP™ Distal Fibula Plates are part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. Available in stainless steel or titanium, these plates are anatomically pre-contoured for the lateral and posterolateral aspects of the distal fibula.LCP™ Proximal Femur Plate (4.5/5.0mm) Variable Angle LCP™ Ankle Trauma System (2.7 mm/3.5 mm) 3.5 mm LCP ® Anterolateral Distal Tibia Plates; 3.5 mm Variable Angle LCP ® Proximal Tibia Plate; 4.5 mm LCP ® Proximal Tibia Plate; Continuous Compression Implants for Trauma Applications; TomoFix ® Medial High Tibia Plate; Power Tools. UNIUM ...4.5 mm LCP® Proximal Tibia Plates - synthes.vo.llnwd.netWe would like to show you a description here but the site won't allow us.synthes.vo.llnwd.netDEVICE DESCRIPTION: The Synthes Titanium 4.5mm LCP Proximal Tibia Plating System consists of 4.5 mm Titanium LCP Proximal Tibia Plates, 5.0 mm Titanium Cannulated Locking and Conical screws, and 4.0 mm and 5.0 mm Titanium Solid Locking screws . The Tibia Plates are contoured to match the anatomy of the proximal tibia with a limited contact low ...About DePuy Synthes. DePuy Synthes, part of the Johnson & Johnson Medical Devices Companies, provides one of the most comprehensive orthopaedics portfolios in the world. DePuy Synthes solutions, in specialties including joint reconstruction, trauma, craniomaxillofacial, spinal surgery and sports medicine, are designed to advance patient care ...VA Locking Anterior Patella Plate 2.7 can be used in conjunction with the following screw implants: Variable Angle Locking Screw B 2.7 mm Cortex Screw B 2.7 mm In addition, for non-load bearing fragments: Variable Angle Locking Screw B 2.4 mm Cortex Screw B 2.4 mm Synthes has not assessed compatibility with devices provided by other manufactur-Titanium Cannulated Tibial Nails-EX, with Proximal bend, sterile Patient Information: J7976-F 5/13 Inventory Control Form Titanium Cannulated Tibial Nail-EX, with Proximal bend 8.0 mm diameter LENGTH LENGTH 04.034.231S 255 mm 04.034.234S 270 mm 04.034.237S 285 mm 04.034.240S 300 mm 04.034.243S 315 mmAbout This Product. Synthes Calcaneal Plate family including VA Locking Calcaneal Plates 2.7 and Variable Angle Locking Anterolateral Calcaneal Plate 2.7 is intended for temporary fixation, correction, or stabilization of the Calcaneus. Get in Touch with a Sales Consultant.Therapeutic indications: Fractures of the proximal tibia in adults and adolescents with closed growth plates including - Proximal split, depression or split-depression fractures - Bicondylar or pure metaphyseal fractures - Associated metaphyseal or associated shaft fractures - Periprosthetic fractures.Inventory Control Form 2.7 mm Variable Angle Locking Calcaneal Plating System Implants 2.7 mm Variable Angle Locking Screws, self-tapping, with T8 StarDriveTM Recess 2.7 mm Variable Angle Locking Calcaneal Plates Right Left Size Length 02.211.400 02.211.401 Small 58 mm 02.211.402 02.211.403 Medium 64 mm 02.211.404 02.211.405 Large 70 mmIn February, active inventory rose 68% above a year ago; Austin, Las Vegas and San Antonio are first markets to recover pandemic inventory shortag... In February, active inventory ...Find out more on the 3.5mm LCP® Superior Anterior Clavicle Plate and Superior Clavicle Plate developed by DePuy Synthes with locking screw technology. Skip to main content Intended for Healthcare Professionals. Companies Search ... Inventory Control Form (Titanium) View PDF . Surgical Technique Guide Synthes/Limelight - 3.5 mm LCP® Superior ...The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant.Placa VA LCP para tibia proximal 3.5 Sistema de bloqueo VA para artrodesis intercarpiana Placas LCP de ángulo variable de artrodesis para MTP 1 2.4/2.7 Placa LCP de ángulo variable para radio distal dorsal 2.4 Sistema de placas LCP de ángulo variable para antepié y mesopié 2.4/2.7 Placa LCP de ángulo variable de malla 2.4/2.7Indices Commodities Currencies Stocksthe VA-LCP drill sleeve and key into the cloverleaf design of the VA locking hole (1). Use the funnel-shaped end of the VA-LCP drill sleeve to drill variable angle holes at the desired angle (2). Alternatively, use the freehand VA-LCP drill sleeve and insert it fully into the VA locking hole (3). Drill variable angle holes at the desired angle (4).Introduction Operative management of posterior tibial plateau fractures (PTPF) remains challenging. The treatment goal is to restore the alignment and articular congruence, and providing sufficient stability which allows early mobilization. The purpose of this study was to assess the feasibility and safety of the newly developed WAVE posterior proximal tibia plate. Methods Between Oct 2017 and ...3.5 mm VA-LCP Proximal Tibia Plates, Small Bend HOLES LENGTH SIDE 02.127.310 4 87 mm right 02.127.311 4 87 mm left 02.127.320 6 117 mm right 02.127.321 6 117 mm left 02.127.330 8 147 mm right 02.127.331 8 147 mm left 02.127.340 10 177 mm right 02.127.341 10 177 mm left 02.127.350 12 207 mm right 02.127.351 12 207 mm left 02.127.360 14 237 mm rightVariable Angle LCP™ Elbow System. Product Codes: 02.107.002, 02.107.002S, 02.107.102... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle LCP™ Elbow System utilizes the variable angle locking technology platform that is based on a common approach to implant design and instrumentation, reducing complexity and ensuring a familiar ...2.7mm va-lcp distal tibia t-plate/6 holes-sterile synthes gmbh. fda.report › gudid › synthes gmbh › h67902118307s0. ... 3.5mm va-lcp prox tibia trial implant-small bend/3h/rt: h679031270110: stopper for 3.5mm va-lcp prox tibia plate aiming arm: h679031270100:Synthes Proximal Tibia Plates. Shipped with USPS Ground Advantage. Synthes Proximal Tibia Plates. Shipped with USPS Ground Advantage. Skip to main content. Shop by category. Shop by category. Enter your search keyword. Advanced: Daily Deals; Brand Outlet; Gift Cards; Help & Contact; Sell; Watchlist Expand Watch ...Synthes Proximal Tibia Plates. Shipped with USPS Ground Advantage. Synthes Proximal Tibia Plates. Shipped with USPS Ground Advantage. Skip to main content. Shop by category. Shop by category. Enter your search keyword. Advanced: Daily Deals; Brand Outlet; Gift Cards; Help & Contact; Sell; Watchlist Expand Watch ...The standard locking tibial nail has a cylindrical proximal end with a Herzog bend of 11 degrees and provisions for locking bolts. However, with the introduction of newer nails with multidirectional locking options in the distal and proximal ends (e.g., Synthes Expert Tibial Nail), the indications have expanded to fractures of ends of long ...Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S …TFNA - Proximal Femoral Nailing System The Universal Nail System Titanium/Stainless Steel Elastic Nail System UFN Unreamed Femoral Nail CFN Cannulated Femoral Nail UHN/PHN Humeral Nailing System UTN/CTN Solid/Cannulated Tibial Nail Please read these instructions for use, the Synthes brochure "Important Informa-tion" carefully before use.At DePuy Synthes, our mission is to keep people moving through innovations in orthopaedic surgery, support and education for providers, and a dedication to improving diversity, inclusivity, and equality throughout the healthcare system. With new advancements in orthopaedic devices, medical technology, and digital surgery across the continuum of care, we are proud to provide surgeons with ...03.231.016. Sechskantschraubenzieher-Einsatz. 4.0 mm, durchbohrt, Länge 180 mm, für Sechskantkupplung 6.0 mm. Ein Loch im Zielbügelaufsatz auswählen und durch das Loch eine Inzision anlegen. Um die durchbohrte VA-Verriegelungsschraube 5.0 mm in variablem Winkel einzubringen, die VA-Führungsbüchse.synthes.vo.llnwd.netsynthes.vo.llnwd.netAA Medical Store improves healthcare around the world by supplying refurbished state-of the-art surgical devices at the best price, with the best warranty, and unmatched service and support.quarter (lateral and medial) of the tibia as well as segmental fractures of the proximal tibia. The 4.5 mm version may also be used for fixation of nonunions and malunions of the medial proximal tibia and tibia shaft, as well as opening and closing wedge tibial osteotomies. 6 Synthes Large Fragment LCP Instrument and Implant Set Technique GuideTitanium Cannulated Tibial Nails-EX, with Proximal bend, sterile Patient Information: J7976-F 5/13 Inventory Control Form Titanium Cannulated Tibial Nail-EX, with Proximal bend 8.0 mm diameter LENGTH LENGTH 04.034.231S 255 mm 04.034.234S 270 mm 04.034.237S 285 mm 04.034.240S 300 mm 04.034.243S 315 mm4.5 mm VA LCP Curved Condylar Plates Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Holes Length 02.124.406 6, Right 159 mm 02.124.407 6, Left 159 mm 02.124.408 8, Right 195 mm 02.124.409 8, Left 195 mm 10, Right 230 mm 230 mm 266 mm 266 mm 301 mm 301 mm 336 mm 336 mm 370 mm 370 mmThe Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant.Inventory Control Form. 3.5 mm VA-LCP Proximal Tibia Plate System. Patient Information: Synthes (USA) To Order: (800) 523-0322. Synthes (Canada) Ltd. To Order: (800) 668-1119. Date: Hospital: Surgeon: Procedure: Implants. 3.5 mm VA-LCP Proximal Tibia Plates, Small Bend 3.5 mm VA-LCP Proximal Tibia Plates, Large Bend.The aim of this study was to evaluate the clinical and/or radiologic outcome using different polyaxial locking plates for the treatment of proximal tibia fractures, the Non-Contact-Briding plate (NCB-PT®) by Zimmer or the Variable Angle Locking Compression Plate (VA-LCP®) by Synthes. This study enrolled 28 patients with proximal tibia fractures (AO/ OTA 41 B-C) and indication for locking ...The DePuy Synthes 4.5 mm Variable Angle (VA) LCP® Curved Condylar Plate is part of the VA LCP Periarticular Plating System which merges variable angle locking screw …Complete the preoperative radiographic assessment and prepare the preoperative plan. Determine plate length and Position the patient supine on a radiolucent operating table. 3.5 mm LCP Low Bend Medial Distal Tibia Plates set 01.1 12.062 Tray for LCP Medial Distal Tibial Plate 3.5, low bend (TAN), for Vario Case, without Lid, with Contents 01.1 12.063 …The Synthes 3.5 mm VA-LCP® Proximal Tibia Plate is part of the VA-LCP Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques. The 3.5 mm VA-LCP Proximal Tibia Plate System has many similarities to standard locking fixation methods, with a few important improvements.Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010The FRN-ADVANCED System is intended for treatment of fractures in adults and adolescents in which the growth plates have fused. Intended applications include: Subtrochanteric fractures. Ipsilateral neck/shaft fractures. Femoral shaft fractures. Impending pathologic fractures. Malunions and nonunions. Get in Touch with a Sales Consultant.Tibia Plate with locking screws. 2.7 mm or 3.5 mm cortex screws may also be used as lag screws through the plate by overdrilling the near fragment. Note: To verify that independent lag screws will not interfere with plate placement, evaluate placement with AP and lateral fluoroscopic image. LCP Distal Tibia Plate • Surgical Technique 5Synthes 3.5 mm VA-LCP PROX TIBIA PLATE SMALL BEND/8H/147 mm/LEFT Condition: Used 02.127.231 ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 532.022 Synthes K-Wire Coupling. $50.00 ...O110 02 257 0013. 13. Right. 301,8. Proximal lateral tibia plate is used for fixation Fixation of fractures, nonunions, osteotomies and pseudoarthroses of the proximal tibia.Our LCP™ Hook Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plate features pointed hooks to aid in plate placement and holes for both lag screws and locking screws. Product Specifications. How to Use This Product.4 DePuy ®Synthes 4.5 mm VA LCP Curved Condylar Plate System Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958 ...The LCP Low Bend Medial Distal Tibia Plate 3.5 mm is part of the Synthes Small Fragment LCP system that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. Combi-holes provide the flexibility of axial compression and ...Instruments. 03.010.110 Cannulated StarDrive Screwdriver, T40 357.399 3.2 mm Guide Wire, 400 mm All titanium end caps for the Tibial Nail-EX are available in extension lengths of 0 mm, 5 mm, 10 mm, and 15 mm. They prevent bone ingrowth into the nail and they extend the nail height if it is overinserted.Inventory Control Form 2.7 mm/3.5 mm LCP Distal Fibula Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. DISTFIBICF001 05/22 2 Length 206.028 28 mm 206.030 30 mm 206.035206.014 35 mmLes plaques de verrouillage pour tarse de 2,4/2,7 mm de Synthes sont destinées à la fixation des fractures, aux ostéotomies, aux cas où il y a une absence de consolidation, aux réimplantations et aux arthrodèses de l'os cuboïde, du tarse et de l'os naviculaire, particulièrement en cas d'ostéopénie.The TomoFix Anatomical Medial High Tibial Plate is contoured to provide an anatomical fit. When compared with the TomoFix Standard and small plates, the new design is intended to reduce both implant prominence. and postoperative implant irritation. Fig 1 shows x-rays from one patient. The brands and labels "approved by AO Technical Commission ...The axial loads were applied on the PLFs by a specially designed load-applicator. We employed a VA LCP proximal tibia plate system (Depuy Synthes) containing proximal posterior rafting as in the control group. Our observations agreed with the reported investigations [12, 16, 17] that the posterior fixation was the sternest PLF fixing method ...About This Product. Synthes Calcaneal Plate family including VA Locking Calcaneal Plates 2.7 and Variable Angle Locking Anterolateral Calcaneal Plate 2.7 is intended for temporary fixation, correction, or stabilization of the Calcaneus. Get in Touch with a Sales Consultant.Consult Depuy Synthes's entire LCP Distal Femur / Promixal Lateral Tibia 4.5 catalogue on MedicalExpo. Page: 1/12. Exhibit with us {{>currencyLabel}} Back ... Insert the locking screw through the guiding block. 6 Synthes LCP DF and PLT . Open the catalog to page 8. Product Information Note: Long LCP DF plates from 15-19 holes are available in ...The LCP Low Bend Medial Distal Tibia Plate 3.5 mm is part of the Synthes Small Fragment LCP system that merges locking screw technology with conventional plating techniques. The combi-holes in the LCP plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. Combi-holes provide the flexibility of axial compression and ...The DePuy Synthes 4.5 mm Variable Angle (VA) LCP® Curved Condylar Plate is part of the VA LCP Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques. The 4.5 mm VA LCP Curved Condylar Plate System has many similarities to standard locking fi xation methods, with a fewVariable Angle LCP™ Elbow System. Product Codes: 02.107.002, 02.107.002S, 02.107.102... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle LCP™ Elbow System utilizes the variable angle locking technology platform that is based on a common approach to implant design and instrumentation, reducing complexity and …. Use the Torque Limiter 1.5 Nm (511.115) and the Screwdriver ShVA-LCP Proximal Tibial Plate 3.5. Part of the Synthes Var Instrument assembly. 1. Choose the matching guiding block and place it onto the plate head. Make sure that the three-point locking mech-anism is positioned on the pre-contoured reference points of the plate. 2. Insert a first LCP drill sleeve through the guiding block into the central hole (A) of the plate and tighten it. Device Name: Synthes 3.5 mm VA-LCP Proximal Tibia 03.231.016. Screwdriver Shaft, hexagonal 4.0 mm, cannulated, length 180 mm, for Hexagonal Coupling 6.0 mm. Choose an aiming arm hole and make an incision through it. For off-axis insertion of VA cannulated locking screws. 5.0 mm, insert the VA wire guide 2.5 mm with spheri-cal head into the protection sleeve. The VA-LCP Lateral Distal Fibula Plate will...

Continue Reading